  "tool": "meng-eee.cable_voltage_drop",
  "name": "Cable sizing by voltage drop (CDU-ENG-EEE-900)",
  "answers": "What conductor area keeps the voltage drop within limit over a run, and what is the drop for a given cable?",
  "degree": {
    "id": "competency:meng-eee",
    "code": "CDU-ENG-EEE-900",
    "name": "Master of Engineering — Electrical & Electronic Engineering",
    "version": "1.0.2"
  },
  "reference": "ΔV = √3 · I · L · ρ / A (3-phase) or 2 · I · L · ρ / A (single-phase), resistive approximation",
  "endpoint": "/faculty/meng-eee/cable_voltage_drop",
  "feeSt": 1,
  "inputSchema": {
    "type": "object",
    "required": [
      "pan",
      "currentA",
      "lengthM"
    ],
    "properties": {
      "pan": {
        "type": "string",
        "description": "The student PAN — the degree must be held in one of its five slots",
        "pattern": "^[0-9 ]{16,19}$"
      },
      "currentA": {
        "type": "number",
        "description": "Load current (A)",
        "minimum": 0.1
      },
      "lengthM": {
        "type": "number",
        "description": "One-way run length (m)",
        "minimum": 0.1
      },
      "systemVoltageV": {
        "type": "number",
        "description": "System voltage (line-to-line for 3-phase) (V)",
        "minimum": 12,
        "default": 400
      },
      "phases": {
        "type": "string",
        "description": "single or three",
        "enum": [
          "single",
          "three"
        ],
        "default": "three"
      },
      "conductor": {
        "type": "string",
        "description": "copper or aluminium",
        "enum": [
          "copper",
          "aluminium"
        ],
        "default": "copper"
      },
      "maxDropPercent": {
        "type": "number",
        "description": "Allowed voltage drop (%)",
        "minimum": 0.5,
        "maximum": 10,
        "default": 3
      }
    },
    "additionalProperties": false
  },
  "outputSchema": {
    "type": "object",
    "required": [
      "minAreaMm2",
      "standardAreaMm2",
      "dropAtStandardV",
      "dropAtStandardPercent"
    ],
    "properties": {
      "minAreaMm2": {
        "type": "number",
        "description": "Minimum conductor area for the limit (mm²)"
      },
      "standardAreaMm2": {
        "type": "number",
        "description": "Next standard conductor size (mm²)"
      },
      "dropAtStandardV": {
        "type": "number",
        "description": "Voltage drop with the standard size (V)"
      },
      "dropAtStandardPercent": {
        "type": "number",
        "description": "The same drop (%)"
      }
    },
    "additionalProperties": false
  },
  "example": {
    "currentA": 250,
    "lengthM": 80
  }
}