  "tool": "meng-civil.column_euler",
  "name": "Column buckling (Euler) (CDU-ENG-CIV-900)",
  "answers": "What axial load buckles a slender column, and what is the safe load with a factor of safety?",
  "degree": {
    "id": "competency:meng-civil",
    "code": "CDU-ENG-CIV-900",
    "name": "Master of Engineering — Civil & Structural Engineering",
    "version": "1.0.0"
  },
  "reference": "P_cr = π²EI/(KL)²; K = 1 pinned-pinned, 0.5 fixed-fixed, 0.7 fixed-pinned, 2 fixed-free",
  "endpoint": "/faculty/meng-civil/column_euler",
  "feeSt": 1,
  "inputSchema": {
    "type": "object",
    "required": [
      "pan",
      "lengthM",
      "iCm4"
    ],
    "properties": {
      "pan": {
        "type": "string",
        "description": "The student PAN — the degree must be held in one of its five slots",
        "pattern": "^[0-9 ]{16,19}$"
      },
      "lengthM": {
        "type": "number",
        "description": "Unbraced length (m)",
        "minimum": 0.1
      },
      "eGpa": {
        "type": "number",
        "description": "Elastic modulus (GPa)",
        "minimum": 1,
        "default": 200
      },
      "iCm4": {
        "type": "number",
        "description": "Least second moment of area (cm⁴)",
        "minimum": 0.01
      },
      "endCondition": {
        "type": "string",
        "description": "End restraint",
        "enum": [
          "pinned-pinned",
          "fixed-fixed",
          "fixed-pinned",
          "fixed-free"
        ],
        "default": "pinned-pinned"
      },
      "factorOfSafety": {
        "type": "number",
        "description": "Factor of safety on buckling",
        "minimum": 1,
        "maximum": 10,
        "default": 2.5
      },
      "appliedLoadKn": {
        "type": "number",
        "description": "Applied axial load (kN)",
        "minimum": 0
      }
    },
    "additionalProperties": false
  },
  "outputSchema": {
    "type": "object",
    "required": [
      "effectiveLengthM",
      "criticalLoadKn",
      "safeLoadKn",
      "appliedOk"
    ],
    "properties": {
      "effectiveLengthM": {
        "type": "number",
        "description": "KL (m)"
      },
      "criticalLoadKn": {
        "type": "number",
        "description": "Euler critical load (kN)"
      },
      "safeLoadKn": {
        "type": "number",
        "description": "Critical load ÷ factor of safety (kN)"
      },
      "appliedOk": {
        "type": "boolean",
        "description": "Applied load ≤ safe load (true when no load given)"
      }
    },
    "additionalProperties": false
  },
  "example": {
    "lengthM": 3.5,
    "iCm4": 800,
    "appliedLoadKn": 200
  }
}